Skip to content
YanSyn Intelligence Technology (Shanghai) Co., Ltd. — moisture-proof cabinets, nitrogen cabinets and industrial drying ovens.
Get a quote

YSN 450 Nitrogen Cabinet 450L (YSN450)

450L nitrogen cabinet holding 1–60% RH to stop oxidation during storage.

24 小时内回复 · 您的信息严格保密

YSN450 nitrogen cabinet, 450L anti-static dual-flow nitrogen purge cabinet with transparent door, flow meter and digital controller for moisture-sensitive components

Product overview

450L of inert storage. Nitrogen purging displaces oxygen and moisture so finished parts, lead frames and sensitive components keep a bright surface between processes.

Humidity is held across 1–60% RH without a compressor, so shelves stay vibration-free.

External 900*600*1010 mm, internal 855*570*840 mm, 3 shelves over 4 layers, 50 kg per shelf. Add F to the model code for the anti-static version.

Built for round-the-clock nitrogen storage:

  • Continuous duty — rated for 24/7 operation. With the composite humidity-control unit it keeps dehumidifying through a power failure, useful on lines with frequent door opening.
  • Service-friendly control — a sealed plug-in module with imported core components keeps service and upgrades quick.
  • Unattended, low-cost running — a high-brightness display shows live temperature and humidity, low-voltage control keeps operation safe, and the low-power core cuts lifetime energy cost.
  • Industry 4.0 ready — dual humidity control with an optional RS485/MES link for traceability; the anti-static (F) coating meets SJ/T10694-2006.

Design advantages built into every YSN nitrogen cabinet

  • Intelligent Dehumidification

    Sensor-driven control holds 1%–60% RH within ±3% and purges nitrogen only when humidity rises.

  • Energy Saving

    Pulsed purging with dual flow meters cuts nitrogen use by up to 50% against continuous-flow cabinets.

  • Anti-Static

    Optional ESD coating 10⁶–10⁹ Ω (add F to the model code) protects static-sensitive PCBs and lead frames.

YanSyn YSN series anti-oxidation nitrogen cabinets in four sizes from 100L to 1430L, each with a digital humidity controller, nitrogen flow meter and glass doors
  • Anti-Oxidation

    Continuous nitrogen purge keeps oxygen below 1%, so solderable surfaces stay bright between processes.

  • Silent Operation

    Compressor-free design runs without vibration, frost or condensate — safe for precision parts and shared labs.

  • Moisture-proof & Mold-proof

    Magnetic sealing strip and positive nitrogen pressure block moisture regain even with the cabinet switched off.

Product Feature

Nitrogen Purge, Fast Dehumidification

Nitrogen Purge, Fast Dehumidification

Nitrogen purge displaces oxygen and moisture before oxidation can start.

Holds 1-60% RH on demand, far below the corrosion threshold of most metals.

Suits SMT reels, PCB panels, wafers, BGA and optical parts.

No compressor inside, so shelves stay vibration-free while purging.

Touch HMI for Nitrogen and Humidity

Touch HMI for Nitrogen and Humidity

One HMI screen sets humidity setpoint, purge timing and alarm limits.

Live temperature and humidity readings stay visible without opening the door.

Modular plug-and-play control box runs on 12V for safe maintenance.

Silent, low-power operation suits labs and production floors.

Magnetic Seal Holds Nitrogen Inside

Magnetic Seal Holds Nitrogen Inside

Built-in magnetic gasket seals all four door edges against nitrogen loss.

The strip resists aging, so the seal stays tight after years of use.

Nitrogen stays inside longer, cutting purge cycles and gas consumption.

ESD-Safe, Precision-Built Cabinet

ESD-Safe, Precision-Built Cabinet

Anti-static coating of 10^6-10^9 ohm meets industry ESD standards.

Add F to the model code for a blue-grey anti-static cabinet finish.

Argon-arc welding gives a smooth, flat, gas-tight cabinet body.

Ideal for PCBs, wafers, optics and other ESD-sensitive loads.

Adjustable Shelves, Flexible Capacity

Adjustable Shelves, Flexible Capacity

Shelf height adjusts to fit tall or irregular parts without wasted space.

Extra shelves can be added later as your storage mix changes.

Choose 100L to 1430L to match wafer, reel or panel throughput.

5mm Tempered Glass Door, Clear View

5mm Tempered Glass Door, Clear View

5mm explosion-proof tempered glass door stays sturdy under daily use.

High clarity lets you check parts at a glance and open the door less.

Push-Type Concealed Safety Lock

Push-Type Concealed Safety Lock

Press-type concealed latch opens with one touch and sits flush.

Keyed opening keeps stored wafers and samples access-controlled.

Universal Casters, Stable When Parked

Universal Casters, Stable When Parked

Double-bearing universal casters roll easily across production floors.

Each caster carries up to 100kg; brakes lock the cabinet in place.

Large cabinets add height-adjustable legs for level, stable loading.

Baosteel Body, Anti-Oxidation Finish

Baosteel Body, Anti-Oxidation Finish

Baosteel 1.2mm cold-rolled steel plate carries heavy shelf loads.

Full acid washing plus powder coating and baking resist corrosion.

A tight painted body keeps the nitrogen atmosphere stable for years.

Dual Flow Meters, 50% Nitrogen Saved

Dual Flow Meters, 50% Nitrogen Saved

Intelligent dual flow-meter control adjusts N2 supply to actual load.

The unit drops to semi-sleep once the humidity setpoint is reached.

Nitrogen use falls by more than 50% versus conventional N2 cabinets.

Lower gas cost per cabinet, lower cost per stored wafer.

Specifications

Capacity (L) Model Humidity range (RH) Power (W) External W*D*H (mm) Internal W*D*H (mm) Door Shelves Storage layers Load per shelf (kg) Inquiry
450LYSN4501%-60%18900*600*1010855*570*840Double door, 1 tier3450 Quote

Add F to the model code for the anti-static version (blue grey, 10⁶–10⁹ Ω). Other customisation on request.

Scroll sideways to compare all columns.

General specifications

Colour
Standard: ivory white; anti-static (F): blue grey
Anti-static coefficient
10⁶ – 10⁹ Ω
Humidity accuracy
≤ ±3% RH (display range 0–99% RH)
Temperature accuracy
≤ ±1 ℃ (display only, −9–99 ℃)
Power supply
AC110V/220V, 50Hz/60Hz (auto-ranging)

Standard and optional

Anything marked optional can be built in. Tell us what you need.

Function Base model Anti-static (F)
Door lockStandardStandard
5 mm explosion-proof tempered glass doorStandardStandard
Cold-rolled steel cabinetStandardStandard
LCD displayStandardStandard
Temperature & humidity sensorStandardStandard
1 MΩ grounding wireStandardStandard
Anti-static coatingOptionalStandard
Interior lightingOptionalOptional
Over-humidity / over-temperature alarmOptionalOptional
MES integrationOptionalOptional
Smart access controlOptionalOptional
Rapid nitrogen purgingOptionalOptional
RS232 / 485 monitoringOptionalOptional
Code lock (electronic / mechanical)OptionalOptional
Stainless steel / acrylic bodyOptionalOptional

Standard Optional Not available

Order & delivery

Standard terms for this range. Confirmed in writing on the quotation.

Lead time
15~20 Working days
MOQ
1 Unit
Packing
Exported-grade wooden case
Shipping
FOB Shanghai
Payment
30% deposit,T/T
Warranty & spares
2 Years

Documents

Specifications, drawings and guides for this range.

All documents

Common questions

How often should the sensor be calibrated?

Calibration intervals are normally set by your own quality system rather than by the cabinet: an ISO 9001 or customer-audited process usually defines how often instruments must be verified. A common starting point is annual verification against a reference, adjusted to whatever your audit actually requires. Tell us your calibration requirement when ordering and we will confirm what documentation accompanies the unit.

What is the difference between the standard model and the F version?

The F suffix denotes the anti-static build. In the standard model the cabinet is finished in ivory white; the F version uses a blue-grey finish and holds surface resistivity between 10⁶ and 10⁹ Ω, with a 1 MΩ earth lead fitted as standard. Everything else is shared: the same door lock, 5 mm tempered glass window, cold-rolled steel body, LCD display, sensor and dehumidifier. The F build is what you specify when handling ESD-sensitive components, where a static discharge would do the damage that the humidity control is preventing.

What power supply do the cabinets require?

The cabinets auto-sense mains voltage and accept AC 110 V or 220 V at 50 or 60 Hz, so the same unit works on either supply without a step-down transformer or an internal change. Power draw is modest and depends on capacity and grade — a 100 L grade A cabinet draws 10 W, while the largest 1430 L grade C cabinet draws 78 W. The figure for each model is listed in the specification table. The ovens are different: models up to 240 L run on single-phase AC 220 V, and from 420 L upward on three-phase AC 380 V.

How much weight can each shelf carry?

Shelf load ratings rise with cabinet size: 20 kg per shelf at 100–160 L, 30 kg at 240 L, 40 kg at 320 L, 50 kg at 450–730 L, 60 kg at 880 L and 100 kg at 1430 L. The number of shelves also increases with capacity — from one shelf in the 100 L models to five in the 730 L and larger units, giving up to six storage tiers. If your load is denser than the standard rating, tell us the weight and we will confirm what the frame can take or specify reinforcement.

Are the cabinets suitable for storing lithium batteries?

Low-humidity storage is standard practice for lithium cells and battery components, where moisture uptake degrades both the electrolyte and the electrode materials. Grade C (1–10% RH) is the usual specification for this work, and a nitrogen cabinet is common where oxidation of bare lithium or current-collector foils is also a concern. One point to be clear about: a dry cabinet controls humidity and atmosphere. It is not a fire-rated or explosion-proof enclosure, and it is not a substitute for the safety controls your process requires. Tell us the cell format and quantity and we will confirm the right configuration.

Can the cabinets be used in a cleanroom?

Yes — the cabinet is a closed steel enclosure with a tempered glass window and an internal dehumidifier, so it does not add particles to the room. Stainless steel and acrylic body constructions are available as options where the cleanroom protocol calls for them. If your facility has a specific particle or outgassing requirement, tell us the class and the applicable standard and we will confirm the build that satisfies it.

All questions

Need a configuration that is not listed?

Most of our shipments are built to order. Send the requirement and we will confirm feasibility within 24 hours.

Get a quote

Enquire about this series

Enquiring about: YSN 450 Nitrogen Cabinet 450L (YSN450)

More contact details (optional)

24 小时内回复 · 您的信息严格保密

WhatsApp Get a quote